Lightning Resistant Series | ||||
Type | NSTP | NSTR | NTTP | NTTR |
Appearance of installation | Built-in type without case | Stationary case available | Built-in type without case | Stationary case available |
Number of phases | Single Phase | Single Phase | 3-phase | 3-phase |
Linear | 2-wire | 2-wire | 3 lines | 3 lines |
Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Rated Input Voltage | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) |
Rated Output Voltage | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) |
Output Capacity | 500~10KVA | 500~10KVA | 5~50KVA | 5~50KVA |
(By designation) | (By designation) | (By designation) | (By designation) | |
Heat resistance class | H | H | H | H |
Surge transition rate (balance) | -60dB or less | -60dB or less | -60dB or less | -60dB or less |
(3KV 1.2×50μS) | (3KV 1.2×50μS) | (3KV 1.2×50μS) | (3KV 1.2×50μS) | |
Impulse withstand voltage | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) |
Efficiency | More than 90% below 5KVA | More than 90% below 5KVA | More than 90% below 5KVA | More than 90% below 5KVA |
5KVA or more, 95% or more | 5KVA or more, 95% or more | 5KVA or more, 95% or more | 5KVA or more, 95% or more | |
Insulation resistance | 100MΩ or more at DC1000V megger | 100MΩ or more at DC1000V megger | 100MΩ or more at DC1000V megger | 100MΩ or more at DC1000V megger |
Dielectric strength | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) |
Lightning Resistant Series | ||||
Type | NSTP | NSTR | NTTP | NTTR |
Appearance of installation | Built-in type without case | Stationary case available | Built-in type without case | Stationary case available |
Number of phases | Single Phase | Single Phase | 3-phase | 3-phase |
Linear | 2-wire | 2-wire | 3 lines | 3 lines |
Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Rated Input Voltage | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) |
Rated Output Voltage | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) | 100~400V (as specified) |
Output Capacity | 500~10KVA | 500~10KVA | 5~50KVA | 5~50KVA |
(By designation) | (By designation) | (By designation) | (By designation) | |
Heat resistance class | H | H | H | H |
Surge transition rate (balance) | -60dB or less | -60dB or less | -60dB or less | -60dB or less |
(3KV 1.2×50μS) | (3KV 1.2×50μS) | (3KV 1.2×50μS) | (3KV 1.2×50μS) | |
Impulse withstand voltage | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) | Primary side to secondary side/ground: 30KV (excluding arrester, 1.2 x 50μS) |
Efficiency | More than 90% below 5KVA | More than 90% below 5KVA | More than 90% below 5KVA | More than 90% below 5KVA |
5KVA or more, 95% or more | 5KVA or more, 95% or more | 5KVA or more, 95% or more | 5KVA or more, 95% or more | |
Insulation resistance | 100MΩ or more at DC1000V megger | 100MΩ or more at DC1000V megger | 100MΩ or more at DC1000V megger | 100MΩ or more at DC1000V megger |
Dielectric strength | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) | Primary side to secondary side/ground AC1000V (excluding arrester, 1 minute) |
NTTR type 3 phase Stand-alone type Cased | ||||||
Model | Output capacity KVA | Body dimensions | Mass Kg | Body dimensions | Mass (kg) | |
(W×D×H)mm | ||||||
NTTR-5K | 5K | 550×450×600 | 110 | 420×500×349 | 65 | |
NTTR-10K | 10K | 600×500×750 | 150 | |||
NTTR-15K | 15K | 600×500×750 | 170 | |||
NTTR-20K | 20K | 600×500×750 | 190 | |||
NTTR-30K | 30K | 650×550×800 | 240 | |||
NTTR-50K | 50K | 700×600×800 | 320 |